Princip i uloga visokonaponskog odvodnika?


(1) Uloga visokonaponskog odvodnika linije

Visokonaponski odvodnik za 6 ~ 220kV AC dalekovodi, je novi tip gromobrana okačen i postavljen na prenosni toranj.

Transmission line arrester: mainly insulated zinc oxide arrester.

Distribution line arrester: valve type arrester, tube type arrester, zinc oxide arrester, itd.

The main role of the high-voltage line arrester is

Limit high-voltage line lightning overvoltage.

Improve the level of high-voltage line lightning resistance.

Reduce the tripping rate caused by lightning faults in the system.

(2) The Principle Of High-Voltage Line Arrester

A high-voltage line arrester has two forms.

One is usually installed in parallel with the line insulator string, the arrester can be connected in series to form a gap. And make the breakdown voltage is lower than the insulator string flashover voltage.

So that the high-voltage line arrester in the insulator string before the flashover breakdown, its installation is as follows.

Another is the gapless arrester directly into the system, the use of arrester resistance nonlinear this characteristic to protect the insulator string. Both can improve the level of lightning resistance of transmission lines, and thus reduce the rate of lightning tripping, increase the reliability of transmission line operation.

High-voltage line arrester and high-voltage line insulators in parallel. When the lightning strike arrester action, the residual voltage of the arrester is lower than 50% of the insulator string discharge voltage. Even if the lightning current increases, the residual voltage of the arrester only slightly increased, the insulator still does not occur flashover. After the lightning flow, the frequency continuation current flowing through the arrester is only milliampere, the frequency continuation current flowing through the arrester extinguishes at the first time over zero, will not trip, the system returns to normal.

The following figure illustrates the high-voltage line arrester and high-voltage line insulator volt-seconds characteristics of the cooperation relationship. The volt-second characteristics of the arrester than the insulator volt-second characteristics of more than 15% lower, when the backlash, can be lower than 20%.

    ZMSWACABES

    Recent Posts

    Budućnost obnovljive energije: Trendovi & Inovacija

    Kako obnovljiva energija nastavlja da dobija zamah, its future will be shaped not just by

    6 months ago

    Objašnjena obnovljiva energija: Tipovi, Prednosti, i ključni izazovi

    I. Uvod U svijetu koji se suočava s dvostrukim izazovima klimatskih promjena i iscrpljivanja resursa,…

    6 months ago

    Vodič za odabir poljoprivredne kablove i inteligentno održavanje

    3. Kako odabrati pravi kabel za poljoprivredne primjene 3.1 Select Cable Type Based

    7 months ago

    Vodič za poljoprivredne kablove: Koristi i glavne karakteristike

    Driven by the global wave of agricultural modernization, agricultural production is rapidly transforming from traditional

    7 months ago

    Pojačajte rudnik desnim rudarskim kablovima

    Kako se globalna rudarska industrija i dalje širi, mining cables have emerged as the critical

    8 months ago

    Vodič za aplikacije elektrotehnike

    Uvod: Važnost elektrotehnike i uloge ZMS kablovskog elektrotehnike, as

    8 months ago