Important! What You Need To Know About The Role Of Shielding In Control Cables


EN shielded control cable is generally used as the connection line of electrical instruments.
It is suitable for the connection line of electrical instruments with an AC-rated voltage of 450/750V and below and the transmission line of the automatic control system.
It has excellent properties such as oil resistance, water resistance, wear resistance, acid and alkali resistance, resistance to various corrosive gases, aging resistance, and non-combustibility.

EN shielded control cable is a cable with a layer of mesh copper or metal wire woven around one or more wires. This layer of mesh metal wire can prevent lightning strikes and external signals cannot interfere with it.

The shield also provides some leakage protection. If the cable is damaged during use and leaks, the shield can direct the leakage current to the ground wire, providing some safety protection.

The role of shielding and grounding wire of shielded control cable is that the shielding layer is divided into internal shielding and external shielding.

They are both to make good contact between the cable conductor and insulation layer, and between the cable insulation layer and the inner protective layer, to eliminate the increase of surface electric field strength caused by the unsmooth surface of the conductor and the inner protective layer.

Product characteristics of shielded control cables.

(1) Allowable bending radius of the cable: the minimum bending radius of a non-armored cable is 6 times the outer diameter of the cable. Fluoroplastic insulated and sheathed cables should be at least 8 gange den ydre diameter på kablet. Copper tape shielded or steel tape armored cable should be at least 12 gange den ydre diameter på kablet.

(2) Maximum operating temperature: polytetrafluoroethylene propylene (F46) insulation should not exceed 200 ℃. Soluble polytetrafluoroethylene (PFA) insulation should not exceed 260 ℃.

(3) Minimum ambient temperature. PVC sheath: fixed laying -40℃, non-fixed laying -15℃. Fluorine plastic and silicone rubber sheath: fixed laying -60℃, non-fixed laying -20℃. Cable installation and laying temperature shall not be lower than 0℃ (fluoroplastic, silicone rubber and nitrile sheathed cable shall not be lower than -25℃).

    zmswacables

    Recent Posts

    Fremtiden for vedvarende energi: Tendenser & Innovation

    As renewable energy continues to gain momentum, its future will be shaped not just by

    6 months ago

    Vedvarende energi forklaret: Typer, Fordele, og vigtige udfordringer

    jeg. Introduction In a world facing the twin challenges of climate change and resource depletion,…

    6 months ago

    Vejledning til valg af landbrugskabel og intelligent vedligeholdelse

    3. Sådan vælger du det rigtige kabel til landbrugsapplikationer 3.1 Select Cable Type Based

    7 months ago

    Landbrugskabelguide: Anvendelser og hovedfunktioner

    Drevet af den globale bølge af landbrugsmodernisering, agricultural production is rapidly transforming from traditional

    7 months ago

    Øg din mine med de rigtige minedriftkabler

    Efterhånden som den globale mineindustri fortsætter med at ekspandere, mining cables have emerged as the critical

    8 months ago

    En guide til elektrotekniske applikationer

    Introduction: The Importance of Electrical Engineering and the Role of ZMS Cable Electrical engineering, as

    8 months ago