Information

Important! Ce que vous devez savoir sur le rôle du blindage dans les câbles de commande


UN shielded control cable is generally used as the connection line of electrical instruments.
It is suitable for the connection line of electrical instruments with an AC-rated voltage of 450/750V and below and the transmission line of the automatic control system.
It has excellent properties such as oil resistance, water resistance, résistance à l'usure, acid and alkali resistance, resistance to various corrosive gases, résistance au vieillissement, and non-combustibility.

UN shielded control cable is a cable with a layer of mesh copper or metal wire woven around one or more wires. This layer of mesh metal wire can prevent lightning strikes and external signals cannot interfere with it.

The shield also provides some leakage protection. If the cable is damaged during use and leaks, the shield can direct the leakage current to the ground wire, providing some safety protection.

The role of shielding and grounding wire of shielded control cable is that the shielding layer is divided into internal shielding and external shielding.

They are both to make good contact between the cable conductor and insulation layer, and between the cable insulation layer and the inner protective layer, to eliminate the increase of surface electric field strength caused by the unsmooth surface of the conductor and the inner protective layer.

Product characteristics of shielded control cables.

(1) Allowable bending radius of the cable: the minimum bending radius of a non-armored cable is 6 times the outer diamètre du câble. Fluoroplastic insulated and sheathed cables should be at least 8 fois le diamètre extérieur du câble. Copper tape shielded or steel tape armored cable should be at least 12 fois le diamètre extérieur du câble.

(2) Maximum operating temperature: polytetrafluoroethylene propylene (F46) insulation should not exceed 200 ℃. Soluble polytetrafluoroethylene (PFA) insulation should not exceed 260 ℃.

(3) Minimum ambient temperature. PVC sheath: fixed laying -40℃, non-fixed laying -15℃. Fluorine plastic and silicone rubber sheath: fixed laying -60℃, non-fixed laying -20℃. Cable installation and laying temperature shall not be lower than 0℃ (fluoroplastic, silicone rubber and nitrile sheathed cable shall not be lower than -25℃).

    câbles zmswac

    Recent Posts

    Avenir des énergies renouvelables: Tendances & Innovation

    Alors que les énergies renouvelables continuent de prendre de l'élan, its future will be shaped not just by

    4 months ago

    Énergie renouvelable expliquée: Types, Avantages, et les principaux défis

    je. Introduction dans un monde confronté aux jumeaux défis du changement climatique et de l'épuisement des ressources,…

    4 months ago

    Guide de la sélection des câbles agricoles et de la maintenance intelligente

    3. Comment choisir le bon câble pour les applications agricoles 3.1 Select Cable Type Based

    5 months ago

    Guide du câble agricole: Utilisations et fonctionnalités principales

    Tiré par la vague mondiale de la modernisation agricole, agricultural production is rapidly transforming from traditional

    5 months ago

    Boostez votre mine avec les bons câbles miniers

    Alors que l'industrie minière mondiale continue de se développer, mining cables have emerged as the critical

    6 months ago

    Un guide des applications de génie électrique

    Introduction: L'importance du génie électrique et le rôle du génie électrique du câble ZMS, as

    7 months ago