Informasi

penting! Apa Sampeyan Kudu Ngerti Babagan Peran Shielding Ing Kabel Kontrol


A kabel kontrol shielded umume digunakake minangka jalur sambungan instrumen listrik.
Cocog kanggo saluran sambungan instrumen listrik kanthi voltase AC 450 / 750V lan ngisor lan saluran transmisi sistem kontrol otomatis..
Nduwe sifat sing apik kayata tahan minyak, tahan banyu, nyandhang resistance, resistance asam lan alkali, resistance kanggo macem-macem gas korosif, resistance tuwa, lan non-combustibility.

A kabel kontrol shielded is a cable with a layer of mesh copper or metal wire woven around one or more wires. This layer of mesh metal wire can prevent lightning strikes and external signals cannot interfere with it.

The shield also provides some leakage protection. If the cable is damaged during use and leaks, the shield can direct the leakage current to the ground wire, providing some safety protection.

The role of shielding and grounding wire of shielded control cable is that the shielding layer is divided into internal shielding and external shielding.

They are both to make good contact between the cable conductor and insulation layer, and between the cable insulation layer and the inner protective layer, to eliminate the increase of surface electric field strength caused by the unsmooth surface of the conductor and the inner protective layer.

Product characteristics of shielded control cables.

(1) Allowable bending radius of the cable: the minimum bending radius of a non-armored cable is 6 times the outer diameteripun saka kabel. Fluoroplastic insulated and sheathed cables should be at least 8 kaping diameter njaba kabel. Copper tape shielded or steel tape armored cable should be at least 12 kaping diameter njaba kabel.

(2) Maximum operating temperature: polytetrafluoroethylene propylene (F46) insulation should not exceed 200 ℃. Soluble polytetrafluoroethylene (PFA) insulation should not exceed 260 ℃.

(3) Minimum ambient temperature. PVC sheath: fixed laying -40℃, non-fixed laying -15℃. Fluorine plastic and silicone rubber sheath: fixed laying -60℃, non-fixed laying -20℃. Cable installation and laying temperature shall not be lower than 0℃ (fluoroplastic, silicone rubber and nitrile sheathed cable shall not be lower than -25℃).

    zmswacables

    Recent Posts

    Masa depan energi sing bisa dianyari: Tren & Inovasi

    Minangka energi sing bisa dianyari terus entuk momentum, its future will be shaped not just by

    9 months ago

    Energi sing dianyari diterangno: Jinis, Mupangate, lan tantangan utama

    Aku. Pambuka ing jagad sing ngadhepi tantangan kembar babagan owah-owahan iklim lan penurunan sumber daya,…

    9 months ago

    Pandhuan kanggo pilihan kabel lan pangopènan sing cerdas

    3. Cara milih kabel sing cocog kanggo aplikasi pertanian 3.1 Select Cable Type Based

    10 months ago

    Pandhuan kabel Pertanian: Nggunakake lan fitur utama

    Didorong dening gelombang modernisasi pertimbangan pertanian pertukaran, agricultural production is rapidly transforming from traditional

    10 months ago

    Ningkatake mine karo kabel pertambangan sing tepat

    Minangka industri pertambangan global terus berkembang, mining cables have emerged as the critical

    11 months ago

    Pandhuan kanggo aplikasi Teknik Listrik

    Pambuka: Pentinge Teknik Elektro lan Peran Teknik Listrik Kabel ZMS, as

    11 months ago