Informatiounen

Al Dirigent Komposit Kär Kabel (ACCC) Virdeel Aféierung


Am Moment, Overhead Kabele gi benotzt fir Stroum iwwer laang Distanzen ze transportéieren. Konventionell Kabele si meeschtens Aluminiumleiter Stahl verstäerkt (Acsr). Zënter den 1990er Joren, Kuelestofffaser Kompositkären (Al Dirigent Komposit Kär) goufen als Kärbar vu Kabelen benotzt. ACCC huet déi folgend Virdeeler iwwer traditionell Dirigenten.

1. High strength and lightweight.

The tensile strength of ordinary steel wire is 1240~1410MPa, while the carbon fiber composite core of the ACCC conductor is twice the former, and its specific gravity is only 1/4 of steel. The weight per unit length of ACCC conductors of the same specification is 10%~20% lighter than conventional ACSR conductors. This allows the tower span of overhead cable to grow, reducing the number of towers by about 16% while reducing the footprint.

2. High conductivity and low transmission loss.

Under the same outer diameter, the cross-sectional area of ACCC’s aluminum strand is 1.29 times that of conventional wires. Dofir, the load capacity is increased by about 29%. Because ACCC wire does not have the magnetic loss caused by the wire material and the resistance heat effect. Zousätzlech, it has a lower operating temperature for the same load, which reduces transmission losses by about 6%. Also, because ACCC uses trapezoidal aluminum wire, its appearance is smoother than ACSR’s round aluminum wire. The surface roughness coefficient is improved, thus increasing the corona onset voltage of the wire and reducing the corona loss.

3. Low arc sag, reducing sag by more than twice.

ACCC wire has significantly low relaxation characteristics compared to conventional wire. Under high-temperature conditions, the arc sag is less than 12% of steel-core aluminum-stranded wire. It can effectively reduce the insulation space of the overhead line corridor, improve the safety and reliability of the wire operation.

4. Korrosiounsbeständegkeet.

ACSR’s aluminum wire and steel core due to long-term exposure to the air. The surrounding environment will corrode the metal material, thus reducing the strength of the wire and affecting the life of the wire. Carbon fiber composite core does not rust, corrosion Resistenz, overcoming the corrosion of galvanized steel stranded wire core. And it also avoids the electrochemical corrosion problem between the aluminum wire and galvanized steel wire when the conductor is energized. Better solve the aging problem of long-term operation of the wire, the service life is higher than the ordinary wire twice.

    zmswacables

    Recent Posts

    Zukunft vun erneierbaren Energien: Trends & Innovatioun

    Wéi erneierbar Energien weider Dynamik gewannen, its future will be shaped not just by

    6 months ago

    Erneierbar Energie erkläert: Zorte, Virdeeler, a Schlëssel Erausfuerderungen

    ech. Aféierung An enger Welt mat den Zwillingserausfuerderunge vum Klimawandel a Ressourceausschöpfung,…

    6 months ago

    Guide fir Landwirtschaft Cable Auswiel an intelligent Ënnerhalt

    3. Wéi wielen ech de richtege Kabel fir landwirtschaftlech Uwendungen 3.1 Select Cable Type Based

    7 months ago

    Landwirtschaft Kabel Guide: Benotzt an Haapt Fonctiounen

    Ugedriwwe vun der globaler Welle vun der landwirtschaftlecher Moderniséierung, agricultural production is rapidly transforming from traditional

    7 months ago

    Boost Your Mine with the Right Mining Cables

    As the global mining industry continues to expand, mining cables have emerged as the critical

    8 months ago

    A Guide to Electrical Engineering Applications

    Aféierung: The Importance of Electrical Engineering and the Role of ZMS Cable Electrical engineering, as

    8 months ago