എ shielded control cable is generally used as the connection line of electrical instruments.
It is suitable for the connection line of electrical instruments with an AC-rated voltage of 450/750V and below and the transmission line of the automatic control system.
It has excellent properties such as oil resistance, water resistance, പ്രതിരോധം ധരിക്കുക, acid and alkali resistance, resistance to various corrosive gases, പ്രായമാകൽ പ്രതിരോധം, and non-combustibility.
എ shielded control cable is a cable with a layer of mesh copper or metal wire woven around one or more wires. This layer of mesh metal wire can prevent lightning strikes and external signals cannot interfere with it.
The shield also provides some leakage protection. If the cable is damaged during use and leaks, the shield can direct the leakage current to the ground wire, providing some safety protection.
The role of shielding and grounding wire of shielded control cable is that the shielding layer is divided into internal shielding and external shielding.
They are both to make good contact between the cable conductor and insulation layer, and between the cable insulation layer and the inner protective layer, to eliminate the increase of surface electric field strength caused by the unsmooth surface of the conductor and the inner protective layer.
Product characteristics of shielded control cables.
(1) Allowable bending radius of the cable: the minimum bending radius of a non-armored cable is 6 times the outer diameter of the cable. Fluoroplastic insulated and sheathed cables should be at least 8 times the outer diameter of the cable. Copper tape shielded or steel tape armored cable should be at least 12 times the outer diameter of the cable.
(2) Maximum operating temperature: polytetrafluoroethylene propylene (F46) insulation should not exceed 200 ℃. Soluble polytetrafluoroethylene (PFA) insulation should not exceed 260 ℃.
(3) Minimum ambient temperature. പിവിസി ഷീറ്റ്: fixed laying -40℃, non-fixed laying -15℃. Fluorine plastic and silicone rubber sheath: fixed laying -60℃, non-fixed laying -20℃. Cable installation and laying temperature shall not be lower than 0℃ (fluoroplastic, silicone rubber and nitrile sheathed cable shall not be lower than -25℃).
As renewable energy continues to gain momentum, its future will be shaped not just by…
ഐ. Introduction In a world facing the twin challenges of climate change and resource depletion,…
3. കാർഷിക ആപ്ലിക്കേഷനുകൾക്കായി ശരിയായ കേബിൾ എങ്ങനെ തിരഞ്ഞെടുക്കാം 3.1 Select Cable Type Based…
Driven by the global wave of agricultural modernization, agricultural production is rapidly transforming from traditional…
As the global mining industry continues to expand, mining cables have emerged as the critical…
Introduction: The Importance of Electrical Engineering and the Role of ZMS Cable Electrical engineering, as…