Important! What You Need To Know About The Role Of Shielding In Control Cables


A shielded control cable is generally used as the connection line of electrical instruments.
It is suitable for the connection line of electrical instruments with an AC-rated voltage of 450/750V and below and the transmission line of the automatic control system.
It has excellent properties such as oil resistance, water resistance, wear resistance, acid and alkali resistance, resistance to various corrosive gases, aging resistance, and non-combustibility.

A shielded control cable is a cable with a layer of mesh copper or metal wire woven around one or more wires. This layer of mesh metal wire can prevent lightning strikes and external signals cannot interfere with it.

The shield also provides some leakage protection. If the cable is damaged during use and leaks, the shield can direct the leakage current to the ground wire, providing some safety protection.

The role of shielding and grounding wire of shielded control cable is that the shielding layer is divided into internal shielding and external shielding.

They are both to make good contact between the cable conductor and insulation layer, and between the cable insulation layer and the inner protective layer, to eliminate the increase of surface electric field strength caused by the unsmooth surface of the conductor and the inner protective layer.

Product characteristics of shielded control cables.

(1) Allowable bending radius of the cable: the minimum bending radius of a non-armored cable is 6 times the outer diameter of the cable. Fluoroplastic insulated and sheathed cables should be at least 8 mara kipenyo cha nje cha cable. Copper tape shielded or steel tape armored cable should be at least 12 mara kipenyo cha nje cha cable.

(2) Maximum operating temperature: polytetrafluoroethylene propylene (F46) insulation should not exceed 200 . Soluble polytetrafluoroethylene (PFA) insulation should not exceed 260 .

(3) Minimum ambient temperature. PVC sheath: fixed laying -40℃, non-fixed laying -15℃. Fluorine plastic and silicone rubber sheath: fixed laying -60℃, non-fixed laying -20℃. Cable installation and laying temperature shall not be lower than 0℃ (fluoroplastic, silicone rubber and nitrile sheathed cable shall not be lower than -25℃).

    zmswacables

    Recent Posts

    Baadaye ya nishati mbadala: Mwenendo & Uvumbuzi

    As renewable energy continues to gain momentum, its future will be shaped not just by

    4 months ago

    Nishati mbadala ilielezea: Aina, Faida, na changamoto muhimu

    I. Introduction In a world facing the twin challenges of climate change and resource depletion,…

    4 months ago

    Mwongozo wa uteuzi wa cable ya kilimo na matengenezo ya akili

    3. How to Choose the Right Cable for Agricultural Applications 3.1 Select Cable Type Based

    5 months ago

    Mwongozo wa Cable ya Kilimo: Matumizi na huduma kuu

    Driven by the global wave of agricultural modernization, agricultural production is rapidly transforming from traditional

    5 months ago

    Kuongeza mgodi wako na nyaya sahihi za madini

    As the global mining industry continues to expand, mining cables have emerged as the critical

    6 months ago

    Mwongozo wa Maombi ya Uhandisi wa Umeme

    Utangulizi: The Importance of Electrical Engineering and the Role of ZMS Cable Electrical engineering, as

    7 months ago