Je! Kwa nini nyaya za juu haziwezi kuzikwa chini ya ardhi?


Je! Ni kebo gani ya voltage ya juu?

Uwasilishaji wa voltage ya juu inahusu matumizi ya 500 Viwango vya voltage ya KV-1000 kV kusambaza umeme.

Ikiwa 220 Index ya maambukizi ya KV ni 100%, Uwekezaji wa jamaa kwa kilomita ya maambukizi ya UHV, Gharama ya jamaa kwa maambukizi ya umeme wa saa moja kilomita mia na matumizi ya vifaa vya chuma, nk., zimepunguzwa sana, na kiwango cha utumiaji wa ukanda wa mstari kimeboreshwa sana.

Katika maisha yetu ya kila siku, Mara nyingi tunaweza kuona mradi wa juu wa upitishaji wa voltage ya juu, Ikiwa tumefikiria juu ya swali: Kwa nini haiwezi kuwa kama mji wa chini ya ardhi, Mistari ya nguvu ya juu-voltage yote imezikwa chini ya ardhi?

The current underground cables are generally of lower voltage levels.

The transmission of lines with high voltage levels is often overhead, which is mainly a factor of cost and technology.   

Underground cables are more complex than the structure of overhead lines, with high technical requirements, Viwanda, and construction difficulties, coupled with the cable buried underground, it is not easy to find faults, overhaul, and maintenance are also more difficult.

And in terms of cost, generally, the same voltage level of the underground cable costs 3 kwa 5 times higher than the overhead lines.   

Characteristics Of High-Voltage Transmission Lines

In particular, our common high-voltage level lines are typically used for long-distance transmission.

If underground cables are used, especially for long-distance transmission regularly through complex terrain, the costs and technical requirements can even skyrocket.   

On the other hand, also the underground cable itself is inherently “hard”.

Overhead lines in the air in good thermal conditions, while the air around the underground cable does not flow, difficult to dissipate heat, which largely limits the level of power underground cables can transmit.

The important thing is that ultra-high voltage transmission has not been able to find an effective insulation material to do the outer skin insulation layer of the wire.

Kwa hivyo, ultra-high voltage wires are bare and cannot be buried buy underground.

There are distributed capacitances around the wires, through which the current can leak out.

On the one hand to increase consumption, on the other hand, if any animal is closed, there will also be the risk of electrocution.

Air is an insulation, but the earth is a conductor. In overhead lines, it is enough to put the wire directly there.

But in the underground, add a layer of insulation shell outside the wire, otherwise, the electricity in the wire did not go far, and the leakage of electricity will leak all that is left.

Underground cables are more complex than the structure of overhead lines, with high technical requirements, Viwanda, and construction difficulties, coupled with the cable buried underground, not easy to find faults, overhaul, and maintenance are also more difficult.

Kwa ujumla, the cost of underground cables of the same voltage level will be several times or even tens of times that of aerial high-voltage lines.

Ultra-high voltage cables buried underground have both safety and economic problems.

If a fault occurs, its inspection and repair of the cable is a very large project and cannot afford to toss and turn.

Kwa hivyo, the current UHV cables should be hung high in the air.

Muhtasari

Underground cable conductors outsourced insulation and protective layer manufacturing are very strict, the human body’s normal contact with the outer skin of the cable will not have any danger.

Cable laying is also very careful, the cable is mostly buried in a special cable trench, cable row pipe, or cable tunnel, subject to good safety isolation and protection.

The depth is mostly less than half a meter, and the higher the voltage level, the deeper the cable is buried.

Moreover, there will be a cable work well or a cable marker stake as a marker every few dozen meters on the ground where the cable is buried to remind people of safety.

Kwa hivyo, underground cables mainly do not cause danger to residents.

    zmswacables

    Recent Posts

    Baadaye ya nishati mbadala: Mwenendo & Uvumbuzi

    As renewable energy continues to gain momentum, its future will be shaped not just by

    4 months ago

    Nishati mbadala ilielezea: Aina, Faida, na changamoto muhimu

    I. Introduction In a world facing the twin challenges of climate change and resource depletion,…

    4 months ago

    Mwongozo wa uteuzi wa cable ya kilimo na matengenezo ya akili

    3. How to Choose the Right Cable for Agricultural Applications 3.1 Select Cable Type Based

    5 months ago

    Mwongozo wa Cable ya Kilimo: Matumizi na huduma kuu

    Driven by the global wave of agricultural modernization, agricultural production is rapidly transforming from traditional

    5 months ago

    Kuongeza mgodi wako na nyaya sahihi za madini

    As the global mining industry continues to expand, mining cables have emerged as the critical

    6 months ago

    Mwongozo wa Maombi ya Uhandisi wa Umeme

    Utangulizi: The Importance of Electrical Engineering and the Role of ZMS Cable Electrical engineering, as

    7 months ago