Important! What You Need To Know About The Role Of Shielding In Control Cables


A shielded control cable is generally used as the connection line of electrical instruments.
It is suitable for the connection line of electrical instruments with an AC-rated voltage of 450/750V and below and the transmission line of the automatic control system.
It has excellent properties such as oil resistance, water resistance, wear resistance, acid and alkali resistance, resistance to various corrosive gases, aging resistance, and non-combustibility.

A shielded control cable is a cable with a layer of mesh copper or metal wire woven around one or more wires. This layer of mesh metal wire can prevent lightning strikes and external signals cannot interfere with it.

The shield also provides some leakage protection. If the cable is damaged during use and leaks, the shield can direct the leakage current to the ground wire, providing some safety protection.

The role of shielding and grounding wire of shielded control cable is that the shielding layer is divided into internal shielding and external shielding.

They are both to make good contact between the cable conductor and insulation layer, and between the cable insulation layer and the inner protective layer, to eliminate the increase of surface electric field strength caused by the unsmooth surface of the conductor and the inner protective layer.

Product characteristics of shielded control cables.

(1) Allowable bending radius of the cable: the minimum bending radius of a non-armored cable is 6 times the outer diameter of the cable. Fluoroplastic insulated and sheathed cables should be at least 8 Kablonun dış çapı. Copper tape shielded or steel tape armored cable should be at least 12 Kablonun dış çapı.

(2) Maximum operating temperature: polytetrafluoroethylene propylene (F46) insulation should not exceed 200 °C. Soluble polytetrafluoroethylene (PFA) insulation should not exceed 260 °C.

(3) Minimum ambient temperature. PVC sheath: fixed laying -40℃, non-fixed laying -15℃. Fluorine plastic and silicone rubber sheath: fixed laying -60℃, non-fixed laying -20℃. Cable installation and laying temperature shall not be lower than 0℃ (fluoroplastic, silicone rubber and nitrile sheathed cable shall not be lower than -25℃).

    zmswacables

    Recent Posts

    Yenilenebilir enerjinin geleceği: Trendler & Yenilik

    Yenilenebilir enerji ivme kazanmaya devam ederken, its future will be shaped not just by

    4 months ago

    Yenilenebilir Enerji Açıklandı: Türler, Faydalar, ve temel zorluklar

    BEN. İklim değişikliği ve kaynak tükenmesinin ikiz zorluklarıyla karşı karşıya olan bir dünyada giriş,…

    4 months ago

    Tarım Kablosu Seçimi ve Akıllı Bakım Kılavuzu

    3. Tarımsal Uygulamalar İçin Doğru Kablo Nasıl Seçilir 3.1 Select Cable Type Based

    5 months ago

    Tarım Kablo Kılavuzu: Kullanımlar ve ana özellikler

    Küresel tarımsal modernizasyon dalgası tarafından yönlendirilen, agricultural production is rapidly transforming from traditional

    5 months ago

    Madenizi doğru madencilik kablolarıyla artırın

    Küresel madencilik endüstrisi genişlemeye devam ederken, mining cables have emerged as the critical

    6 months ago

    Elektrik Mühendisliği Uygulamaları Kılavuzu

    giriiş: Elektrik mühendisliğinin önemi ve ZMS kablosu elektrik mühendisliğinin rolü, as

    7 months ago