Important! What You Need To Know About The Role Of Shielding In Control Cables


A shielded control cable is generally used as the connection line of electrical instruments.
It is suitable for the connection line of electrical instruments with an AC-rated voltage of 450/750V and below and the transmission line of the automatic control system.
It has excellent properties such as oil resistance, water resistance, wear resistance, acid and alkali resistance, resistance to various corrosive gases, aging resistance, and non-combustibility.

A shielded control cable is a cable with a layer of mesh copper or metal wire woven around one or more wires. This layer of mesh metal wire can prevent lightning strikes and external signals cannot interfere with it.

The shield also provides some leakage protection. If the cable is damaged during use and leaks, the shield can direct the leakage current to the ground wire, providing some safety protection.

The role of shielding and grounding wire of shielded control cable is that the shielding layer is divided into internal shielding and external shielding.

They are both to make good contact between the cable conductor and insulation layer, and between the cable insulation layer and the inner protective layer, to eliminate the increase of surface electric field strength caused by the unsmooth surface of the conductor and the inner protective layer.

Product characteristics of shielded control cables.

(1) Allowable bending radius of the cable: the minimum bending radius of a non-armored cable is 6 times the outer diameter of the cable. Fluoroplastic insulated and sheathed cables should be at least 8 times the outer diameter of the cable. Copper tape shielded or steel tape armored cable should be at least 12 times the outer diameter of the cable.

(2) Maximum operating temperature: polytetrafluoroethylene propylene (F46) insulation should not exceed 200 ℃. Soluble polytetrafluoroethylene (PFA) insulation should not exceed 260 ℃.

(3) Minimum ambient temperature. PVC sheath: fixed laying -40℃, non-fixed laying -15℃. Fluorine plastic and silicone rubber sheath: fixed laying -60℃, non-fixed laying -20℃. Cable installation and laying temperature shall not be lower than 0℃ (fluoroplastic, silicone rubber and nitrile sheathed cable shall not be lower than -25℃).

    zmswacables

    Recent Posts

    How to Choose the Right Communication Cable?

    Communication cable, as a transmission medium, is a necessary equipment for completing information projects. Unsuitable…

    2 years ago

    What Is Power Armored Cable? Characteristics of Armored Cable

    Power armored cable is a power cable equipped with a hard armor layer outside the…

    2 years ago

    Tight Spot Circulation Short-Term or Limit Copper Prices Down Space

    Since copper has become a necessity in people's lives, copper prices have also become the…

    2 years ago

    The Difference between Power Fiber Optic Cable and Communication Fiber Optic Cable

    Fiber optic cable is mainly used to realize signal transmission in communication lines. According to…

    2 years ago

    Wire And Cable General Knowledge Q & A

    1. Single-Core Cable Sheath End Grounding Method, Why Must Be Installed Along The Cable Laid…

    2 years ago

    How to Choose Cables for Photovoltaic Systems – PV Cable

    In recent years, the technology in the photovoltaic industry is developing faster and faster. Such…

    2 years ago